{"id":1181,"date":"2025-01-03T00:00:02","date_gmt":"2025-01-02T15:00:02","guid":{"rendered":"https:\/\/www.kwk.co.jp\/lubricat\/?post_type=product&#038;p=341"},"modified":"2025-02-21T15:11:53","modified_gmt":"2025-02-21T06:11:53","slug":"k-series","status":"publish","type":"product-en","link":"https:\/\/www.kwk.co.jp\/lubricat\/en\/product\/k-series\/","title":{"rendered":"Lubricating Oil-Systems"},"content":{"rendered":"<div class=\"specs xm-mg\">\n<h3 class=\"spc-head\">Specifications<\/h3>\n<div class=\"js-scrollable xm-mg\">\n<table class=\"tbl-way way-10\">\n<tbody>\n<tr>\n<th>Model<\/th>\n<th>Method<\/th>\n<th>Oil reservior<\/th>\n<th>Oil Pump<\/th>\n<th>Motor<\/th>\n<th>Filter<\/th>\n<th>Oil cooler<\/th>\n<th>Cooling water<\/th>\n<th>Oil viscocity<\/th>\n<th>Heating device<\/th>\n<\/tr>\n<tr>\n<th>K1<\/th>\n<td>Base Plate Unit<\/td>\n<td>\u2015<\/td>\n<td rowspan=\"3\">1 unit\/Discharge pressure0.55\u33ab<\/td>\n<td rowspan=\"3\">1 unit\/Totally enclosed external fan type E-class three-phase<br class=\"nodis\" \/>50Hz 200V\/400V<br class=\"nodis\" \/>60Hz 200\/220V, 400\/440V<\/td>\n<td rowspan=\"6\">1 unit \/ Filtration accuracy\uff1aequivalent to 150 mesh<\/td>\n<td>1 unit\/Cooling capacity<br class=\"nodis\" \/>48\u2103\u219240\u2103<\/td>\n<td>MAX.32\u2103<br class=\"nodis\" \/>2.5\u33ab<br class=\"nodis\" \/>Industrial water<\/td>\n<td>ISO VG320<\/td>\n<td>\u2015<\/td>\n<\/tr>\n<tr>\n<th>K2<\/th>\n<td>Unit Type<\/td>\n<td>1 unit\/10 times the pump discharge per minute<\/td>\n<td>\u2015<\/td>\n<td>\u2015<\/td>\n<td rowspan=\"5\">ISO VG320\u3001220\u300168<\/td>\n<td rowspan=\"4\">Electric heater<br class=\"nodis\" \/>Heating capacity 5\u00b0C\/hr(when oil is stationary)<\/td>\n<\/tr>\n<tr>\n<th>K3<\/th>\n<td>Unit Type<\/td>\n<td>1 unit\/10 times or 15 times the pump discharge per minute<\/td>\n<td rowspan=\"4\">1 unit\/Cooling capacity<br class=\"nodis\" \/>48\u2103\u219240\u2103<\/td>\n<td rowspan=\"4\">MAX.32\u2103<br class=\"nodis\" \/>2.5\u33ab<br class=\"nodis\" \/>Industrial water<\/td>\n<\/tr>\n<tr>\n<th>K4A<\/th>\n<td>Unit Type<\/td>\n<td rowspan=\"3\">1 unit\/10 times, 15 times, or 30 times the pump discharge per minute<\/td>\n<td rowspan=\"3\">2 units\/Discharge pressure0.55\u33ab<\/td>\n<td rowspan=\"3\">2 units\/Totally enclosed external fan type E-class three-phase50\u3390 200V\/400V<br class=\"nodis\" \/>60\u3390<br class=\"nodis\" \/>200\/220V<br class=\"nodis\" \/>400\/440V<\/td>\n<\/tr>\n<tr>\n<th>K4B<\/th>\n<td>Unit Type<\/td>\n<\/tr>\n<tr>\n<th>K4C<\/th>\n<td>Cellar Type<\/td>\n<td>Steam heater<br class=\"nodis\" \/>Heating capacity 5\u00b0C\/hr(when oil is stationary)<br class=\"nodis\" \/>Pressure 2 MPa saturated steam<\/td>\n<\/tr>\n<tr>\n<th>K5<\/th>\n<td>Cellar Type<\/td>\n<td colspan=\"8\" rowspan=\"2\">Please inquire separately.<\/td>\n<\/tr>\n<tr>\n<th>K6<\/th>\n<td>Cellar Type<\/td>\n<\/tr>\n<tr>\n<th>K7<\/th>\n<td>Unit Type<br class=\"nodis\" \/>(For blower)<\/td>\n<td>1 unit\/10 times the pump discharge per minute<\/td>\n<td>2\u53f0\/Discharge pressure0.55\u33ab<\/td>\n<td>2 units \/ Totally enclosed external fan type E-class three-phase<br class=\"nodis\">50Hz 200V\/400V<br class=\"nodis\">60Hz 200\/220V, 400\/440V<\/td>\n<td>1 unit\/Filtration accuracy\uff1aequivalent to 150 mesh<\/td>\n<td>1 unit\/Cooling 1 unit\/Cooling capacity 48\u2103\u219240\u2103<\/td>\n<td>MAX.32\u2103<br class=\"nodis\" \/>2.5\u33ab<br class=\"nodis\" \/>Industrial water<\/td>\n<td>ISO VG68<\/td>\n<td>\u2015<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"model-img model-two\">\n<figure><img decoding=\"async\" src=\"https:\/\/www.kwk.co.jp\/lubricat\/wp\/wp-content\/uploads\/2025\/01\/k1.jpg\" alt=\"K1\" \/><figcaption>K1<\/figcaption><\/figure>\n<figure><img decoding=\"async\" src=\"https:\/\/www.kwk.co.jp\/lubricat\/wp\/wp-content\/uploads\/2025\/01\/k3.jpg\" alt=\"K3\" \/><figcaption>K3<\/figcaption><\/figure>\n<figure><img decoding=\"async\" src=\"https:\/\/www.kwk.co.jp\/lubricat\/wp\/wp-content\/uploads\/2025\/01\/k4a.jpg\" alt=\"K4A\" \/><figcaption>K4A<\/figcaption><\/figure>\n<figure><img decoding=\"async\" src=\"https:\/\/www.kwk.co.jp\/lubricat\/wp\/wp-content\/uploads\/2025\/01\/k7.jpg\" alt=\"K7\" \/><figcaption>K7<\/figcaption><\/figure>\n<\/div>\n<\/div>\n<div class=\"catalog-info\">\n<p class=\"txt\">PDF files of catalogues are available.<\/p>\n<p class=\"txt\"><a href=\"https:\/\/www.kwk.co.jp\/lubricat\/wp\/wp-content\/uploads\/2024\/12\/catalog-lubricat.pdf\" target=\"_blank\" rel=\"noopener\">View Catalogue<\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Lubrication systems are essential for ensuring stable and long-term operation of production equipment across all industries. Our K-series forced circulation lubrication system is a standardized unit designed to meet various applications and scales, enabling quick manufacturing at a low cost.<\/p>\n","protected":false},"author":1,"featured_media":908,"parent":0,"template":"","contents_cate":[72],"class_list":["post-1181","product-en","type-product-en","status-publish","has-post-thumbnail","hentry","prodcat-en-k-series"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.kwk.co.jp\/lubricat\/wp-json\/wp\/v2\/product-en\/1181","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kwk.co.jp\/lubricat\/wp-json\/wp\/v2\/product-en"}],"about":[{"href":"https:\/\/www.kwk.co.jp\/lubricat\/wp-json\/wp\/v2\/types\/product-en"}],"author":[{"embeddable":true,"href":"https:\/\/www.kwk.co.jp\/lubricat\/wp-json\/wp\/v2\/users\/1"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kwk.co.jp\/lubricat\/wp-json\/wp\/v2\/media\/908"}],"wp:attachment":[{"href":"https:\/\/www.kwk.co.jp\/lubricat\/wp-json\/wp\/v2\/media?parent=1181"}],"wp:term":[{"taxonomy":"prodcat-en","embeddable":true,"href":"https:\/\/www.kwk.co.jp\/lubricat\/wp-json\/wp\/v2\/contents_cate?post=1181"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}